Digital multimeter with automatic range selection and analog scale. Thermocouple for measuring temperature. Illumination of scales. Mechanical protection against incorrect connection of the probes. Storing min/max values.
Overload protection: 1000V DC or 750V AC rms
Impedance: ≥10MΩ
600mV
±0.5% of rdg
0.1mV
6V
1mV
60V
10mV
600V
100mV
1000V
±0.8% of rdg
1V
ACV
60mV
±2.0% of rdg
0.01mV
Average sensing, calibrated to rms of sine wave
Frequency: 40~400Hz
Overload protection: 1000V DC or 750V AC rms/Impedance: ≥10MΩ
600mV
0.1mV
6V
±1.5% of rdg
1mV
60V
10mV
600V
100mV
750V
± 2.0% of rdg
1V
DCA
600μA
± 2.0% of rdg
0.1μA
20A up to 10 seconds; 600A range with AC/DC Current Clamp Adapter
Overload protection: 0.8A/250V or 0.75A/250V, 20A/250V fuse
6000μA
1μA
60mA
10μA
600mA
100μA
6A
± 2.5% of rdg
1mA
20A
10mA
600A
± 3.0% of rdg
100mA
ACA
600μA
± 2.0% of rdg
0.1μA
20A up to 10 seconds;600A range with AC/DC Current Clamp Adapter
Average sensing, calibrated to rms of sine wave/Frequency: 40~400Hz
Overload protection: 0.8A/250V or 0.75A/250V, 20A/250V fuse
6000μA
1μA
60mA
10μA
600mA
100μA
6A
± 2.5% of rdg
1mA
20A
10mA
600A
± 3.5% of rdg
100mA
Resistance
Range
Accuracy
Resolution
Overload protection: 250V DC or AC rms
600Ω
± 1.2% of rdg
0.1Ω
6kΩ
1Ω
60kΩ
10Ω
600kΩ
100Ω
6MΩ
1kΩ
60MΩ
±2.5% of rdg
10kΩ
Capacitance
Range
Accuracy
Resolution
Overload protection: 250V DC or AC rms
40nF
± 3.5% of rdg
10pF
400nF
± 2.5% of rdg
100pF
4µF
1nF
40µF
± 5.0% of rdg
10nF
400µF
100nF
4000µF
1µF
Diode and Audible continuity test
Range
Description
Test condition
Overload protection: 250V DC or AC rms
Display read
Approximately forward voltage of diode
Forward DC current
approx. 0.4mA
Reversed DC voltage
approx. 2.8V
Built-in buzzer sounds if resistance is less than 100Ω
Open circuit voltage
approx. 0.5V
Frequency
Range
Accuracy
Resolution
Overload protection: 250V DC or AC rms
10Hz
± 0.5% of rdg
0.01Hz
100Hz
0.1Hz
1000Hz
1Hz
10kHz
10Hz
100kHz
100Hz
1000kHz
1kHz
10MHz
10kHz
Temperature
Range
Accuracy
Resolution
Overload protection: 250V DC or AC rms
℃/℉
¦
Leave your feedback or ask a question
Only this product is discussed here. Off topic comments will be deleted! Please follow the Commenting Rules.
The data presented in the product description are for reference only and may differ from those indicated by the manufacturer.
To carry out technical calculations and obtain the exact parameters of the goods, use the datasheets from the manufacturer's website.
If you need additional information, or you found an error in the description, or have other questions about this product, then our manager will help you: Ярослав
unknown